See All of This Company's Exhibits
Exhibit 99 Test Results from Vartest Lab VARTEST LABORATORIES INC Specializing in Fiber, Yarn, Fabric & Apparel Testing 19 West 36th Street New York, N.Y. 10018 Phone: (212) 947-8391 (212) 947-8392 Fax: (212) 947-8719 Textile Testing Services Division REPORT OF TEST DATE: March 10, 1999 FILE: CONNEC. AO30199A CLIENT: RMF Global Inc. 223 N. Maine Street Suite 2 Pittsburgh, PA 15215 USA SAMPLE IDENTIFIED BY CLIENT AS: Material Submitted Color White TEST PROCEDURES: TEST RESULTS: FABRIC WEIGHT 0.42 oz/sq yd @ 43.5" (ASTM D3776): = 0.50 oz/lin yd 14.10 grams/sq meter DENSITY: Less than 0.66 MELT POINT: (Fisher Johns Apparatus): - SOFTENING: 88°C Average - MELT: 95°C Average THERMAL RETENTION (ASTM D1518-90, MODIFIED): Clo Value: 2.0 AIR PERMEABILITY (ASTM D737): 0.01 cubic ft./min/sq.ft. POLYMER TYPE BY FTIR: Low Density Polyethylene HIGH RANGE HYDROSTATIC (Federal Standard Test Method 191A-5512): 6.41 psi average RECYCLBILITY: (Based On Literature Search): Recycleable as low density polyethylene (LDPE) Page 1 This Report Is Issued Subject To Terms on Reverse VARTEST LABORATORIES INC Specializing in Fiber, Yarn, Fabric & Apparel Testing 19 West 36th Street New York, N.Y. 10018 Phone: (212) 947-8391 (212) 947-8392 Fax: (212) 947-8719 Textile Testing Services Division REPORT OF TEST DATE: March 1, 1999 FILE: CONNEC. A030999A CLIENT: RMF Global Inc. 223 N. Maine Street Suite 2 Pittsburgh, PA 15215 USA SAMPLE IDENTIFIED BY CLIENT AS: Material Submitted Color White TEST PROCEDURES: TEST RESULTS: MOISTURE VAPOR PERMEABILITY (ASTM E96): 5.00 g/sq meter/24 hrs 45 DEGREE FLAMMABILITY PER PART 1610 OF THE FLAMMABLE FABRICS ACT (PLAIN FABRIC): UNREFURBISHED BURN TIME: (sec) BURN TYPE LENGTH SRU SCREEN DNI REFURBISHED - METHOD ASTM D1230: WIDTH SRU SCREEN DNI BURN TIME (sec) BURN TYPE SRU DNI SRU *IBE SRU *IBE SRU *IBE SRU *IBE SRU *IBE SRU *IBE SRU *IBE SRU *IBE SRU *IBE Average: SRU seconds Average: SRU seconds SIDES OF FABRIC TESTED: FACE FABRIC DIRECTION: LENGTH TEST RESULT: PASS - Class 1, Normal Flammability ABBREVIATIONS FOR PLAIN FABRIC BURN TYPE: IBE - Ignited but extinguished. *IBE - Ignited but extinguished, burn goes under cord without breaking it. DNI - Did not ignite. BB - Base Burn NOTE: SRU = Stop Cord Remains Unbroken - No Burn Time Available Signed For The Company By /s/ Adam R. Varley Adam R. Varley Technical Director GH/03/58...LJ/03 This Report Is Issued Subject To Terms on Reverse VARTEST LABORATORIES INC Specializing in Fiber, Yarn, Fabric & Apparel Testing 19 West 36th Street New York, N.Y. 10018 Phone: (212) 947-8391 (212) 947-8392 Fax: (212) 947-8719 Textile Testing Services Division REPORT OF TEST DATE: August 16, 2000 FILE: CONNEC. AO80800B CLIENT: RMF Global Inc. ATTN: Mr. Joseph Riccelli 223 N. Maine Street Suite 2 Pittsburgh, PA 15215 USA SAMPLE IDENTIFIED BY CLIENT AS: Fabric Sample Submitted Style: Quilted Tricot 1 Layer Eliotex, 1 Layer Non-Woven Scrim Color White/Black TEST PROCEDURES: TEST RESULTS: AIR PERMEABILITY (ASTM D737): 3.21 cubic ft./min/sq. ft. THERMAL RETENTION (ASTM D1518-90): Clo Value: 2.25 MOISTURE VAPOR PERMEABILITY (ASTM E96): 179.2 g/sq meter/24 hrs average [Vartest Laboratories Tested & Evaluated Seal] Signed For The Company By /s/ Adam R. Varley Adam R. Varley Technical Director GR/08/64 This Report Is Issued Subject To Terms on Reverse VARTEST LABORATORIES INC Specializing in Fiber, Yarn, Fabric & Apparel Testing 19 West 36th Street New York, N.Y. 10018 Phone: (212) 947-8391 (212) 947-8392 Fax: (212) 947-8719 Textile Testing Services Division REPORT OF TEST FILE: CONNEC. AO3O199A SAMPLE IDENTIFIED BY CLIENT AS: Material Submitted Color White BIODEGRADABLE: (Based On Literature Search): Limited biodegradability typical of LDPE. THICKNESS: 0.021 inches FILM BREAKING STRENGTH (CPFA-27): - MACHINE DIRECTION: TENSILE STRENGTH @ BREAK: 142 lbs/sq.inch cross section area. AVERAGE ELONGATION @ BREAK: 40.0% - CROSS MACHINE DIRECTION: TENSILE STRENGTH @ BREAK: 47 lbs/sq.inche cross section area. AVERAGE ELONGATION @ BREAK: 51.0% Signed For The Company By /s/ Adam R. Varley Adam R. Varley Technical Director LJ/03/38..EA/03 Page 2 This Report Is Issued Subject To Terms on Reverse